| 678-602-5054 | |
ISCSI to SAS CRS i-S12-R2140-2.5
The CRS i-S12-S/R2140-2.5 provides excellent space and energy efficiency to help SMBs easily deploy budget-friendly IP SANs. Accommodating 12 small form factor (SFF) 2.5-inch drives in a high-density 1U enclosure, the dual-controller CRS i-S12-S/R2140-2.5 delivers optimal performance density. Its enterprise-class data protection and outstanding price-performance can generate significant business advantages.

|
Thin provisioning |
Ensure the most efficient allocation of pooled capacity |
|
Data protection 1.Snapshot 2.Volume copy/Volume mirror 3.Sync and async remote replication |
Support the highest data availability and quick service restart after storage accidents |
| Eight 1GbE iSCSI host ports | Cost-effective storage ideal for high reliability applications |
| Accommodates twelve 2.5-inch drives in a 1U enclosure | Provides enterprise-class performance with high-density configuration |
|
Green design: 1.High-efficiency power supplies 2.Intelligent multi-level drive spin-down technology |
Power supplies delivering more than 80% energy conversion efficiency technology In spin-down state, drives can save up to 60% of energy consumption |
|
CacheSafe technology |
Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure |
| Expansion up to 108 HDDs |
"Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite (SANWatch) support, including multi-pathing functions |
1 Easy management and monitoring of your subsystems anywhere, locally or remote |
|
Multiple monitoring methods |
| Host Ports | Four or Eight 1GbE iSCSI ports |
| Storage Controller | Single or Dual redundant controllers |
| Cache Memory | Default 2GB, up to 8GB |
| Drive Connectivity | Cost-effective storage ideal for high reliability applications |
| Accommodates twelve 2.5-inch drives in a 1U enclosure | Provides enterprise-class performance with high-density configuration |
| Green design: | |
| 1 High-efficiency power supplies | Power supplies delivering more than 80% energy conversion efficiency |
| 2 Intelligent multi-level drive spin-down technology | In spin-down state, drives can save up to 60% of energy consumption |
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
| Expansion up to 108 HDDs | Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite (SANWatch) support, including multi-pathing functions |
1 Easy management and monitoring of your subsystems anywhere, locally or remotely 2 Recognize and manage redundant paths; support path failover and load-balancing |
|
Multiple monitoring methods Real-time problem detection and notification to achieve continuous operation |
6Gb/s SAS connectivity Accommodates 2.5-inch disk drives S.M.A.R.T. support NCQ support Automatic bad-sector reassignment Dedicated bandwidth to each connected drive Drive buffer on/off switch |
| Supported Drives |
300, 450 or 600GB - 2.5" 10,000 RPM 6Gb/s SAS drives 32 or 64 GB - 2.5" 3Gb/s SATA SSD* * MUX board required when using SATA drives |
| Maximum Number of Drives |
Per system: 12 Via JBOD: 108 |
| Form Factor | 1U |
| RAID Functionality |
Global, delicated or enclosure hot-spare RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 Online expansion by: - Adding new drives - Copying and replacing drives with drives of larger |
| Capacity |
RAID migration Configurable stripe size and write policy per system Intelligent drive handling - In degraded mode: skips irreparable blocks to |
| Continue rebuild | - In normal operation: data-block verification and repair |
| Data Services |
Thin provisioning* Local replication ** - Snapshot - Volume copy/ mirror Remote replication* - Synchronous or asynchronous * Optional ** Available with Standard license and optional |
| Advanced license | |
| Green Design |
High-efficiency power supplies Intelligent multi-level drive spin-down |
| Availability and Reliability |
Redundant, hot-swappable hardware modules CacheSafe technology** Multi-pathing support Device mapper support An optional flash backup module needs to be purchased to activate |
| CacheSafe technology | |
| Notification | Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN |
| Management |
Java-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus |
| OS Support |
Windows Server 2003 Windows Server 2008, 2008 R2 (including Hyper-V) RedHat Enterprise Linux SUSE Linux Enterprise Sun Solaris Mac OS X VMware Citrix IBM AIX |
| Service and Support | |
| All raid's ship with 3-year Standard Service |
Standard service: - Hardware warranty - Software update; 8x5 phone, web and email support Upgrade/Extension service*: Replacement part dispatch on the next business day (up to 5 years) - Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day - Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours * Optional ** Service may vary by region |
| Power |
Power supplies: Two 380W DC AC voltage: 115VAC @ 6A to 230VAC @ 3A with PFC (auto-switching) Frequency: 47-63 Hz |
| Environmental |
Temperature: 0 to 40°C operating/ -40 to 60°C non-operating Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m |
| (40,000ft) non-operating | Relative humidity: 5 to 95% non-condensing, operating and non-operating |
| Dimensions |
Without chassis ears / protrusions: 445mm (W) x 44mm (H) x 500mm (D) |
| Weight | Without HDDs:13.36kg (29.41lbs) |
| Package Dimensions | 780mm (W) x 220mm (H) x 590mm (D) |
ISCSI to SAS CRS i-S16-R2142
Featuring 1GbE iSCSI host connectivity and 6Gb/s SAS drive support, the CRS i-S16-S/R2142 provides a budget-friendly choice to help SMB users easily deploy high-availability IP SANs. Accommodating 16 SAS or SATA drives, the dual-controller ESDS S16E-R2142 delivers optimal performance. The enterprise-class data protection and outstanding price-performance of the CRS i-S16-S/R2142 can generate significant business advantages.

|
Thin provisioning |
Ensure the most efficient allocation of pooled capacity |
|
Data protection:
|
Support the highest data availability and quick service restart after storage accidents |
|
Twelve 1GbE iSCSI host ports |
Cost-effective storage ideal for high reliability applications |
| Green design: | |
|
1.High-efficiency power supplies 2.Intelligent multi-level drive spin-down technology |
80 PLUS-certified power supplies delivering more than 80% energy efficiency In spin-down state, drives can save up to 60% of energy consumption |
|
CacheSafe technology |
Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
|
Fault-tolerant hardware modules |
Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
|
Expansion up to 112 HDDs |
"Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
|
Powerful management suite (SANWatch) support, including multi-pathing functions |
|
|
Multiple monitoring methods |
Real-time problem detection and notification to achieve continuous operation |
| Thin provisioning | Ensure the most efficient allocation of pooled capacity |
|
Data protection:
1. Snapshot |
Support the highest data availability and quick service restart after storage accidents |
| Six 1GbE iSCSI host ports | Cost-effective storage ideal for high reliability applications |
|
Green design: 1 High-efficiency power supplies 2 Intelligent multi-level drive spin-down technology |
Power supplies delivering more than 80% energy conversion efficiency In spin-down state, drives can save up to 60% of energy consumption |
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
| Expansion up to 104 HDDs | "Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite support, including multi-pathing functions |
1Easy management and monitoring of your subsystems anywhere, locally or remotely 2 Recognize and manage redundant paths; support path failover and load-balancing |
| Multiple monitoring methods | Real-time problem detection and notification to achieve continuous operation |
| Supported Drives |
300, 450 or 600GB - 3.5" 15,000 RPM 6Gb/s SAS drives |
| Maximum Number of Drives |
Per system: 24 |
| Form Factor | 4U |
| RAID Functionality |
Global, delicated or enclosure hot-spare RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 Online expansion by: - Adding new drives - Copying and replacing drives with drives of larger capacity RAID migration Configurable stripe size and write policy per system Intelligent drive handling - In degraded mode: skips irreparable blocks to continue rebuild |
| Data Services |
Thin provisioning* Local replication ** - Snapshot - Volume copy/ mirror Remote replication* - Synchronous or asynchronous * Optional ** Available with Standard license and optional Advanced license |
| Green Design |
High-efficiency power supplies Intelligent multi-level drive spin-down |
| Availability and Reliability |
Redundant, hot-swappable hardware modules CacheSafe technology** Multi-pathing support (EonPath) Device mapper support ** Optional BBU and flash backup module need to be purchased to activate CacheSafe technology |
|
Notification |
Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN |
| Management |
Java-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus |
| OS Support |
Windows Server 2003 Windows Server 2008, 2008 R2 (including Hyper-V) RedHat Enterprise Linux SUSE Linux Enterprise Sun Solaris Mac OS X VMware Citrix IBM AIX |
|
Service and Support |
|
| All raid's ship with 3-year Standard Service |
Standard service: - Hardware warranty - Software update; 8x5 phone, web and email support Upgrade/Extension service*: Replacement part dispatch on the next business day (up to 5 years) - Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day - Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours * Optional ** Service may vary by region |
| Power |
Power supplies: Three 405W DC AC voltage: 100VAC @ 8A to 240VAC @ 4A with PFC (auto-switching) Frequency: 50-60 Hz |
ISCSI to SAS CRS i-S24-R2142-2.5
The CRS i-S24-R2142-2.5 provides excellent space and energy efficiency to help SMBs easily deploy budget-friendly IP SANs. Accommodating 24 small form factor (SFF) 2.5-inch drives in a high-density 2U enclosure, the dual-controller CRS i-S24-R2142-2.5 delivers optimal performance density. Its enterprise-class data protection and outstanding price-performance can generate significant business advantages.

| Thin provisioning | Ensure the most efficient allocation of pooled capacity |
|
Data protection: 1 Snapshot 2 Volume copy/Volume mirror 3 Sync and async remote replication |
Support the highest data availability and quick service restart after storage accidents |
| Twelve 1GbE iSCSI host ports | Cost-effective storage ideal for high reliability applications |
| Accommodates twenty-four 2.5-inch drives in a 2U enclosure | Provides enterprise-class performance with high-density configuration |
|
Green design: 1 High-efficiency power supplies 2 Intelligent multi-level drive spin-down technology |
Power supplies delivering more than 80% energy conversion efficiency In spin-down state, drives can save up to 60% of energy consumption |
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
| Expansion up to 144 HDDs | "Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite (SANWatch) support, including multi-pathing functions |
1 Easy management and monitoring of your subsystems anywhere, locally or remotely 2 Recognize and manage redundant paths; support path failover and load-balancing |
| Multiple monitoring methods | Real-time problem detection and notification to achieve continuous operation |
| Host Ports | Eight 8Gb/s Fibre Channel ports |
| Storage Controller | Single or Dual redundant controllers |
| Cache Memory | Default 2GB, up to 8GB |
| Drive Connectivity |
6Gb/s SAS connectivity Accommodates 2.5-inch disk drives S.M.A.R.T. support NCQ support Automatic bad-sector reassignment Dedicated bandwidth to each connected drive Drive buffer on/off switch |
| Supported Drives | 300, 450 or 600GB - 2.5" 10,000 RPM 6Gb/s SAS drives |
| Maximum Number of Drives | Per system: 24 |
| Via JBOD: 144 | Corresponding Expansion Enclosure |
| Form Factor | 2U |
| RAID Functionality |
Global, delicated or enclosure hot-spare RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 Online expansion by: - Adding new drives - Copying and replacing drives with drives of larger capacity RAID migration Configurable stripe size and write policy per system Intelligent drive handling - In degraded mode: skips irreparable blocks to continue rebuild - In normal operation: data-block verification and repair |
| Data Services |
Services Thin provisioning* Local replication ** - Snapshot - Volume copy/ mirror Remote replication* - Synchronous or asynchronous * Optional ** Available with Standard license and optional Advanced license |
| Green Design |
1 High-efficiency power supplies 2 Intelligent multi-level drive spin-down |
| Availability and Reliability |
Redundant, hot-swappable hardware modules CacheSafe technology** Multi-pathing support Device mapper support ** An optional flash backup module needs to be purchased to activate CacheSafe technology |
| Notification | Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN |
| Management |
Java-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus |
| OS Support |
Windows Server 2003 Windows Server 2008, 2008 R2 (including Hyper-V) RedHat Enterprise Linux SUSE Linux Enterprise Sun Solaris Mac OS X VMware Citrix IBM AIX |
| Service and Support |
All raid's shipwith 3-year Standard Service Standard service: - Hardware warranty - Software update; 8x5 phone, web and email support Upgrade/Extension service*: Replacement part dispatch on the next business day (up to 5 years) - Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day - Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours * Optional ** Service may vary by region |
| Power |
Power supplies: Two 530W DC AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching) Frequency: 47-63 Hz |
| Environmental |
Temperature: 0 to 40°C operating/ -40 to 60°C non-operating Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating Relative humidity: 5 to 95% non-condensing, operating and non-operating |
| Dimensions |
Without chassis ears / protrusions: 446mm (W) x 88mm (H) x 514mm (D) |
| Weight | Without HDDs:17.32kg (38.18lbs) |
| Package Dimensions | 709mm (W) x 400mm (H) x 528mm (D) |
ISCSI to SAS CRS i-S24-R2240
Featuring 10GbE iSCSI host connectivity and 6Gb/s SAS drive support, the CRS i-S16-S/R2240 model provides a budget-friendly choice to help SMB users easily deploy high-availability IP SANs. Accommodating 16 SAS drives, the dual-controller CRS i-S16-S/R2240 delivers optimal performance. Its enterprise-class data protection and outstanding price-performance can generate significant business advantages.

| Thin provisioning | Ensure the most efficient allocation of pooled capacity |
| Data protection: | |
|
1 Snapshot 2 Volume copy/Volume mirror 3 Sync and async remote replication |
Support the highest data availability and quick service restart after storage accidents |
| Four 10GbE iSCSI host ports | Best-of-class throughput and IOPS, ideal fit for IO-intensive and bandwidth-demanding applications |
| Green design: | |
|
1 High-efficiency power supplies 2 Intelligent multi-level drive spin-down technology |
80 PLUS-certified power supplies delivering more than 80% energy efficiency In spin-down state, drives can save up to 60% of energy consumption |
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant controllers, PSUs, fans; high-availability hardware design, preventing "single-point-of-failure |
| Expansion up to 112 HDDs | Pay-as-you-grow scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite (SANWatch) support, including multi-pathing functions |
1 Easy management and monitoring of your subsystems anywhere, locally or remotely 2 Recognize and manage redundant paths; support path failover and load-balancing |
| Multiple monitoring methods | Real-time problem detection and notification to achieve continuous operation |
| Host Ports | Two or Four 10GbE iSCSI ports |
| Storage Controller | Single or Dual redundant controllers |
| Cache Memory | Default 2GB, up to 8GB |
| Drive Connectivity |
6Gb/s SAS connectivity Accommodates 3.5-inch disk drives S.M.A.R.T. support NCQ support Automatic bad-sector reassignment Dedicated bandwidth to each connected drive Drive buffer on/off switch |
| Supported Drives | 300, 450 or 600GB - 3.5" 15,000 RPM 6Gb/s |
| SAS drives | 300, 450 or 600GB - 2.5" 10,000 RPM 6Gb/s SAS |
| SAS drives | 1,2 or 3TB - 3.5" 7,200 RPM 6Gb/s Nearline |
| Maximum Number of Drives |
Per system: 16 Via JBOD: 112 |
| Form Factor | 3U |
| RAID Functionality |
Global, delicated or enclosure hot-spare RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 Online expansion by: - Adding new drives - Copying and replacing drives with drives of larger capacity RAID migration Configurable stripe size and write policy per system Intelligent drive handling - In degraded mode: skips irreparable blocks to continue rebuild - In normal operation: data-block verification and repair |
| Data Services |
Thin provisioning* Local replication ** - Snapshot Volume copy/ mirror Remote replication* Synchronous or asynchronous * Optional ** Available with Standard license and optional Advanced license |
| Green Design | 80 PLUS-certified power supplies delivering more than 80% energy efficiency |
| Intelligent multi-level drive spin-down | |
| Availability and Reliability |
Redundant, hot-swappable hardware modules CacheSafe technology Multi-pathing support (EonPath) Device mapper support |
| Notification | Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN |
| Management |
Java-based SANWatch management software |
| OS Support |
Windows Server 2003 Windows Server 2008, 2008 R2 (including Hyper-V) RedHat Enterprise Linux SUSE Linux Enterprise Sun Solaris Mac OS X VMware Citrix IBM AIX |
| Service and Support |
All raid's ship with 3-year Standard Service
* Optional |
| Power |
Power supplies: Two 530W DC AC voltage: 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching) Frequency: 47-63 Hz |
| Environmental |
Temperature: 0 to 40°C operating/ -40 to 60°C non-operating Altitude: Sea level to 3660m (12,000ft) operating / sea level to 12,192m (40,000ft) non-operating Relative humidity: 5 to 95% non-condensing, operating and non-operating |
| Dimensions |
Without chassis ears / protrusions: 445mm (W) x 130mm (H) x 514mm (D) |
| Weight | Without HDDs:19.66kg (43.69lbs) |
| Package Dimensions | 779mm (W) x 564mm (H) x 597mm (D) |
ISCSI to SAS CRS i-S24-S2142
Featuring 1GbE iSCSI host connectivity and 6Gb/s SAS drive support, the CRS i-S24-S2142 provides a budget-friendly choice to help SMB users easily deploy IP SANs. Accommodating 24 SAS or SATA drives, the single-controller CRS i-S24-S2142 delivers optimal performance. The enterprise-class data protection and outstanding price-performance of the ESDS S24E-G2142 can generate significant business advantages.

| Thin provisioning | Ensure the most efficient allocation of pooled capacity |
|
Data protection:
1. Snapshot |
Support the highest data availability and quick service restart after storage accidents |
| Six 1GbE iSCSI host ports | Cost-effective storage ideal for high reliability applications |
|
Green design: 1 High-efficiency power supplies 2 Intelligent multi-level drive spin-down technology |
Power supplies delivering more than 80% energy conversion efficiency In spin-down state, drives can save up to 60% of energy consumption |
| CacheSafe technology | Backup battery automatically supplies power to write cached data into flash module for permanent protection during power outage |
| Fault-tolerant hardware modules | Redundant PSUs, fans; high-availability hardware design, preventing "single-point-of-failure" |
| Expansion up to 104 HDDs | "Pay-as-you-grow" scalability; no waste on what you don't need, and no worries about what you will need |
| Powerful management suite support, including multi-pathing functions |
1Easy management and monitoring of your subsystems anywhere, locally or remotely 2 Recognize and manage redundant paths; support path failover and load-balancing |
| Multiple monitoring methods | Real-time problem detection and notification to achieve continuous operation |
| Host Ports |
Six 1GbE iSCSI ports |
| Storage Controller | Single controllers |
| Cache Memory | Default 1GB, up to 4GB |
| Drive Connectivity |
6Gb/s SAS connectivity Accommodates 3.5-inch disk drives S.M.A.R.T. support NCQ support Automatic bad-sector reassignment Dedicated bandwidth to each connected drive Drive buffer on/off switch |
| Supported Drives |
300, 450 or 600GB - 3.5" 15,000 RPM 6Gb/s SAS drives 300, 560 ot 600GB - 2.5" 10,000 RPM 6Gb/s SAS drives 1,2 or 3TB - 3.5" 7,200 RPM 6Gb/s Nearline SAS drives |
| Maximum Number of Drives |
Per System :24 Via JBOD: 104 |
| Form Factor | 4U |
| RAID Functionality |
Global, delicated or enclosure hot-spare RAID levels supported : RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60 Online expansion by: - Adding new drives - Copying and replacing drives with drives of larger capacity RAID migration Configurable stripe size and write policy per system Intelligent drive handling - In degraded mode: skips irreparable blocks to continue rebuild - In normal operation: data-block verification and repair |
| Data Services |
Thin provisioning* Local replication ** - Snapshot - Volume copy/ mirror Remote replication* - Synchronous or asynchronous * Optional ** Available with Standard license and optional Advanced license |
| Green Design |
High-efficiency power supplies Intelligent multi-level drive spin-down |
| Availability and Reliability |
Redundant, hot-swappable hardware modules CacheSafe technology** Multi-pathing support Device mapper support ** optional BBU and flash backup module needs to be purchased to activate CacheSafe technology |
| Notification | Various event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN |
| Management |
Java-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus |
| OS Support |
Windows Server 2003 Windows Server 2008, 2008 R2 (including Hyper-V) RedHat Enterprise Linux SUSE Linux Enterprise Sun Solaris Mac OS X VMware Citrix IBM AIX |
|
Service and Support All raid's shipwith 3-year Standard Service |
Standard service: - Hardware warranty - Software update; 8x5 phone, web and email support Upgrade/Extension service*: Replacement part dispatch on the next business day (up to 5 years) - Advanced Service: 24x7 phone, web and email support + onsite diagnostics on the next business day - Premium Service: 24x7 phone, web and email support + onsite diagnostics in 4 hours * Optional ** Service may vary by region |
| Power |
Power supplies: Two 530W DC AC voltage: 100VAC @ 8A to 240VAC @ 4A with PFC (auto-switching) Frequency: 50--60 Hz |
